Home > Request Test > Components Test for Vehicle
Untitled Document






- Internal Standard for Hyundai, Daewoo, Ssangyong, GM, FORD etc
- Environmental test in accordance with ISO 16750-3/4
- Vehicle EMC Directivity (95/54/EC, 2004/104/EC)
- EU Directivity (97/24/EC)
- Vehicle Security Directivity (95/56/EC)
- CISPR12 : Vehicles, Boats, and Internal Combustion Engine Driven Devices - Radio Disturbance    Characteristics - Limits and Methods of Measurement for the Protection of Receivers Except those    Installed in the Vehicle/Boat/Device Itself or in Adjacent Vehicles/Boats
- CISPR25 : Radio disturbance characteristics for the protection of receivers used on board vehicles,    boats, and on devices - Limits and methods of measurement Second Edition
- ECE Reg. 10.02
- ECE Reg. 97.01



1. ISO7637-1 (1990) : Power Line Conducted Susceptibility test
Pulse 1 -100V, Pulse 2 +100V, Pulse 3a -150V, Pulse3b +100V,
Pulse 4 Vs:-7/Va-6V , Pulse 5 +86.5V (Standard Pulse), Pulse 6 -300V,
Pulse 7 -80V

2. ISO7637-3 (1993) : Signal Line Conducted Susceptibility test
Pulse 3a -150V, Pulse 3b +100V (Standard Pulse)

3. ISO 11452 -2~7 (1993) : Radiated Immunity
¨ç Free Field Test
- Frequency Range :20MHz~4GHz
- Electric Field Strength : 100V/m at 1m
- Location : ALSE
¨è BCI(Bulk Current Injection)
- Frequency Range : 1~400 MHz
- Strength :100mA
- Location : ALSE
¨é Stripe Line
¨ê E-field ANT
- Frequency Range : 0.01~200MHz
- Electric Field Strength : 50V/m
- Location : ALSE

4. ISO/TR 10605 (1993) , ESD
Direct ¡¾ 30kV, Air ¡¾30Kv

5. Emission test in accordance with CISPR 12
6. Emission test in accordance with CISPR 25
7. Environmental test in accordance with ISO 16750-3/4

Emission Test
¡Ý Anchoic Chamber
- Registered lab at FCC and VCCI
   (3m measurement)
¡Ý Test Receiver
- ESCS30 (R&S), BB, NB Automatic measurement SW
¡Ý Measurement Capability
- CISPR 12
- CISPR 25
- SAE J1113-41
- EEC95/54
- GM (GMW3097)
- Ssangyong (SES E922)
- Hyundai (ES96200-00)



Radiated Immunity Test
¡Ý 3mFull Anechoic Chamber
- 10kHz¡­18GHz
¡Ý Amplifier (A.R.)
- 1.2kW(CW)10kHz-220MHz
- 500W(CW) 80 ~ 1000MHz
- 100W(CW) 0.8 ~ 4.2GHz
¡Ý Field Strength(at 1m)
- 10kHz-200MHz 100V/m
- 200MHz-1GHz 200V/m
- 1~4GHz 150V/m
¡Ý Measurement Capability
- ISO 11452-2
- SAE J1113-21
- GM (GMW 3097)
- Ssangyong (SES E 922)
- Hyundai (ES96200-00)
- Renault Samsung (36-00-808/F)


For any questions, please contact us
Email : mscho@koreaemc.com, emc6@koreaemc.com